Summa Series Servodrive Product Manual
Tuning
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
9-12
Figure 9-10
Auto-Tuning Tool flowchart
Start
Load Inertia
Percentage
Set parameters for
reference generator
Check and confirm the
safety of the motion
Use the Auto-Tuning Tool
Result of execution
Save
Success
End
Write
parameters
Yes
No
Execute again
Faulure
No
Yes
The following parameters are automatically adjusted when using the auto-tuning tool.
Parameter
Adjustment method
Write into
Speed Loop Gain
Auto-tuning
Pn102
Speed Loop Integral Time
Auto-tuning
Pn103
Position Loop Gain
Auto-tuning
Pn104
Torque Command Filter Time
Auto-tuning
Pn105
CAUTION
The parameters cannot be changed automatically when using the Auto-
Tuning Tool.
You have to choose whether to save (write) the parameters into the
Drive. If you choose to save, parameters will be changed, but they are
only available for
.
Applicated Case
Applied for the high rigidity (up to 20 times load moment of inertia) equipment.
Applied for the low rigidity (up to 10 times load moment of inertia) equipment.