11-4
Applicable Standards
The safety standards followed by STO are shown in the table below.
Item
Safety Specification
EMC Directive
IEC 61800-3: 2017
IEC 61000-4: 2017
IEC 61326-3-1: 2017
IEC 61800-5-2: 2016
Low Voltage Directive
EN 61800-5-1: 2007 + AMD1:2017
Functional Safety
IEC 61800-5-2: 2016
IEC 60204-1: 2016
IEC 61508: 2010
IEC 62061: 2015
ISO 13849-1: 2015
Environmental Requirements
IEC 60068-2-1: 2007
IEC 60068-2-2: 2007
IEC 60068-2-6: 1995
IEC 60068-2-14: 1984
IEC 60068-2-27: 1987
IEC 60068-2-78: 2001
IEC 61800-2: 2015
IEC 61800-5-1:2007 + AMD1:2016
11.2
Environmental Conditions
Item
Specification
Operation
Temperature: -5
℃
to 55
℃
Humidity: 5% to 95% RH (with no condensation)
Storage
Temperature: -20
℃
to 85
℃
Humidity: 5% to 95% RH (with no condensation)
Altitude
≤
1000m (Rated);
≤
2000m (Derated)
IP
IP20
Pollution Index
II
Overvoltage Category
III
Isolation Voltage
Input to Output: 2 kV; Input to Earth: 2.7 kV
Insolation Resistance
50 VDC, 50 m
Ω
or more
CAUTION
To avoid the risk of crosstalk to signal cables, please segregate the
power interface cable from signal cables or state alternative mitigation
methods.
It is not recommended to use the device in public low voltage power
supply systems.