Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-4
No.
Index
Name
Range
Unit
Default
When Enabled
Pn003
3167
Application Function
Selections 3
0000 to 1032
-
0000
After restart
Pn003.0: Motor Stopping Methods for Gr.1 Alarms, Servo OFF, STO,
and Servo OFF
0
Applying the dynamic brake and then let the Motor coast.
1
Applying the dynamic brake and then place the Motor in DB state.
2
Coast the Motor to a stop.
Pn003.1: Motor Stopping Method for Overtravel
0
Applying the dynamic brake and then let the Motor coast.
1
Coast the Motor to a stop.
2
Applying the reverse brake and then place the Motor in zero
clamping state.
3
Applying the reverse brake and then let the Motor coast.
Pn003.2: Reserved setting (Do not change).
Pn003.3: Overload Enhancement
0
Disabled.
1
Enabled. This function can enhance the Motor load for
instantaneous more than 2 times rated load, which can be used in
the conditions that require frequent start and stop.
This setting is unavailable for EM3A Motors.