Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-18
No.
Index
Name
Range
Unit
Default
When Enabled
Pn212
3238
Resolution of External
Encoder
1 to 1048576
1 pulse
10000
After restart
-
Pn213
3239
Position Deviation Threshold
between Encoder and External
Encoder
0 to 134217728
1 pulse
1000
Immediately
-
Pn214
323A
Position Deviation Clear
between Encoder and External
Encoder
0 to 100
0
%
Immediately
-
Pn304
3294
Inner Speed Reference
-6000 to 6000
rpm
500
Immediately
To set the inner Motor speed reference.
This setting is available when servo is in inner speed control mode (Pn006.0 = 0 and Pn005.1 = 1).
Pn305
3295
Jogging Speed
0 to 6000
rpm
500
Immediately
To set a speed for the Motor in JOG operation, and the rotation direction is determined by the reference.
Pn306
3296
Soft Start Acceleration Time
0 to 10000
ms
0
Immediately
To set ramp acceleration time per 1000 rpm.
Pn307
3297
Soft Start Deceleration Time
0 to 10000
ms
0
Immediately
To set ramp deceleration time per 1000 rpm.
Pn308
3298
Speed Reference Filter Time
0 to 10000
ms
0
Immediately
To set speed reference filter time.
Pn309
3299
S-Curve Rise Time
0 to 10000
ms
0
Immediately
To set a rise time for transiting from one speed point to another speed point in the S-curve.
Pn310
329A
Speed Reference Smooth
Mode Selection
0 to 3
-
0
After restart
[0] Ramp
[1] S-Curve
[2] Primary filtering
[3] Secondary filtering