Summa Series Servodrive Product Manual
CiA402 Drive Profile
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
6-16
Index Subindex Name
Access Data Type Unit
Range
Default
3201
00
Limit for Load
Oscillation
Suppression
RW
INT32
rpm
0 to 1000
100
3169
00
Internal Torque
Feedforward
Method
RW
INT32
-
0 to 3
0
02
Torque
Feedforward
Method
RW
INT32
-
0 to 3
0
03
Speed
Feedforward
Method
RW
INT32
-
0 to 3
0
Recommended Configuration
RPDO
TPDO
Remarks
6040h: Controlword
6041h: Statusword
Mandatory
60C1-01h: 1st set-point
6064h: Position Actual Value
Mandatory
6060h: Mode of Operation
6061h: Modes of Operation Display
Optional