Summa Series Servodrive Product Manual
Tuning
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
9-42
Use the Panel Operator of the Drive
The following are the steps to execute the load inertia identification by using the Panel Operator.
Step 1
Press [
M
] key several times to select the Utility Function Mode.
Step 2
Press [▲] key or [▼] key to select the function number Fn009.
Step 3
Press [◄] key, and Panel Operator displays as below.
Step 4
Press [
M
] key to execute the load inertia identification.
At this time, Panel Operator displays the speed of the Motor in real time.
Step 5
When this operation has been completed, Panel Operator will display the detection result (Unit: %).
NOTE
: You can press the [
M
] key several times to execute this operation until the detection result is confirmed.
Step 6
Press [▲] key to write the detection value to the parameter Pn106 (Load Inertia Percentage).
Step 7
Press [◄] key to return to the display of the Fn009.
Use the ESView V4
The following are the steps to execute the load inertia identification by using ESView V4.
Step 1
Select
Advance
→
Load Inertia Identification
in the
Menu Bar
of the
ESView V4
main windows.