Summa Series Servodrive Product Manual
Basic Settings
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
4-4
Code
Meaning
Safe State
Forward Drive Prohibited
Reverse Drive Prohibited
(Forward and Reverse) Overtravel State
Alarm Number Display
NOTE
: When the Drive is in Servo Alarm State, you shall check and correct the fault according to the Alarm Number
Display, and then, you can press [◄] key to try to clear the current alarm.
4.1.4
Parameter Setting Mode
Functions can be selected or adjusted by setting parameters. There are two types of parameters.
Function Parameters: the functions allocated to each digit of the Panel Operator can be selected.
Adjustment Parameters: a parameter is set to a value within the specified range of the parameter.
For a description of the parameter settings, please refer to the section
Function Parameters Setting
The example below shows how to change parameter Pn003 (Application Function Selections 3) from
0000
to
1032
.
Step 1
Press [
M
] key several times to select the Parameter Setting Mode.
Step 2
Press [▲] key or [▼] key to select the parameter Pn003.
Step 3
Press [◄] key to display the current value of Pn003.
Step 4
Press and hold [◄] key for 1 second or more, and then a flashing decimal point will appear at the bottom
right of the 5th digit.
Decimal point is flashing