Summa Series Servodrive Product Manual
CiA402 Drive Profile
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
6-72
Object
Bit
Name
Value Description
Statusword
6041h
10
Target reached
0
Reserved
12
Drive follows the
command value
0
Drive does not follow the target value (position, velocity
or torque)
1
Drive follows the target value (position, velocity or
torque)
13
Following error
0
No following error
1
Following error
15
Homeflag
0
Homing not completed
1
Homing completed
Index Subindex Name
Access
Data
Type
Unit
Range
Default
603F
00
Error Code
RO
UINT16
-
0 to 65535
0
6040
00
Controlword
RW
UINT16
-
0 to 65535
0
6041
00
Statusword
RO
UINT16
-
0 to 0xFFFF
0
6060
00
Modes of operation
RW
INT8
-
0 to 10
0
6061
00
Modes of Operation
display
RO
INT8
-
0 to 10
0
606C
00
Velocity Actual value
RO
INT32
Reference
unit/s
-
-
6071
00
Target Torque
RW
INT16
0.1%
-32768 to +32768
0
6074
00
Target Demand Value
RO
INT16
0.1%
-
-
6077
00
Torque actual value
RO
INT16
0.1%
-5000 to 5000
0
60B2
00
Torque Offset
RW
INT16
0.1%
–32768 to +32767 0
60E0
00
Positive Torque Limit
Value
RW
UINT16
0.1%
0 to 65535
-
60E1
00
Negative Torque Limit
Value
RW
UINT16
0.1%
0 to 65535
-
31CD
00
Torque Command
Filter Time
RW
INT32
0.01ms
0 to 2500
50
31CA
00
Speed Loop Gain
RW
INT32
rad/s
1 to 10000
500
31CB
00
Speed Loop Integral
Time
RW
INT32
0.1ms
1 to 5000
125