9-5
Applicated Case
Applied for that no more than 30 times the load moment of inertia.
Applied for any rotation speed.
Relevant Parameters
Parameter Setting
Meaning
When Enabled Classification
Pn100.0
1 [Default] Set the
Tuning Mode
as
Tuning-less
. After restart
Function
Application Restrictions
The following functions or applications are not available in the Tuning-less function:
Gain switch is disabled.
P/PI Switch is disabled.
Speed feedback by using observed speed is disabled.
Load Torque Compensation is disabled.
Model Following Control Function is disabled.
9.2.2
One-Parameter Auto-Tuning
Function Description
This tuning function is similar to the tuning-less function, using an Autotune parameters adjustment
module that updates the position loop and speed loop parameters in real time based on the servo operating
state (position, speed, current).
Only the parameter Pn101 (Servo Rigidity) needs to set in One-Parameter Auto-Tuning function, and
Figure 9-5 shows the block diagram in One-Parameter Auto-Tuning.
Figure 9-5
Block diagram in One-Parameter Auto-Tuning
Drive
Position loop
Speed loop
Torque loop
Position
reference
M
Current
Encoder
Motor
Speed
Position
Host
Controller
Autotune parameters
adjustment
Pn106
Pn101
Pn100.0
Before performing One-Parameter Auto-Tuning, you need to manually set the following parameters: