12-15
No.
Index
Name
Range
Unit
Default
When Enabled
Pn170
320E
Acc./Dec. Time for PJOG1
50 to 2000
ms
500
Immediately
-
Pn171
320F
Stop Time for PJOG1
100 to 10000
ms
1000
Immediately
-
Pn172
3210
Turns for Inertia Identification
0 to 1
-
0
Immediately
To set the turns towards the forward direction in Inertia Identification operation.
[0] 8 rotations.
[1] 4 rotations.
Pn173
3211
Frequency of Vibration
Suppression Filter
100 to 2000
Hz
2000
Immediately
-
Pn174
3212
Adjust Bandwidth of Vibration
Suppression Filter
1 to 100
-
30
Immediately
-
Pn175
3213
Vibration Suppression
0 to 500
-
100
Immediately
-
Pn176
3214
Lowpass Filter Time for
Vibration Suppression
0 to 50
0.1ms
0
Immediately
-
Pn177
3215
Highpass Filter Time for
Vibration Suppression
0 to 1000
0.1ms
1000
Immediately
-
Pn178
3216
Damping of Vibration
Suppression Filter
0 to 500
-
100
Immediately
-
Pn179
3217
Amplitude Threshold for
Vibration Detection
5 to 500
-
100
Immediately
This parameter is used for automatic vibration suppression.
Pn180
3218
Frequency Threshold for
Vibration Detection
0 to 100
Hz
100
Immediately