CARE OF YOUR FUJITSU DRIVE

Careful handling  and  installation of your disk drive  is paramount to  the  longevity  of  the  unit.    Serious  damage  can  occur  to  the  internal
mechanisms if forces outside the environmental specifications are exerted to the casing.  In transportation, always use the original packing in
which the drive was supplied and avoid sharp changes in temperature to minimise the risk of condensation.

INSTALLATION

1.  ORIENTATION–

The  drive  can  be  installed  in  each  six  surface  down  orientations.    Inclination  from  vertical  or  horizontal  should  not

exceed 5

°

.

2. MOUNTING SCREW INSTALLATION–

When the mounting screw holes on the side of the drive are used, be sure to use the two pairs

of outer holes.  Do not use the center hole in conjunction with only one of the outer holes.  The screws must not penetrate the drive by more
than 6.35 millimeters.  Impact caused by the electric driver must be within the device specifications.

3. COOLING–

Allow space above and below the drive to provide an adequate air flow.  Fan cooling is recommended.  The disk enclosure

temperature measured at center of base cover (Label side), should never exceed 55°C.

Reference value:
MAN series...

An air flow with a velocity of more than 0.1 m/s is required in an environment of 30°C. (Center of DE cover 

≤ 55

°C)

(at 200 IOPS)

An air flow with a velocity of more than 0.3 m/s is required in an environment of 35°C. (Center of DE cover 

≤ 55

°C)

An air flow with a velocity of more than 0.5 m/s is required in an environment of 40°C. (Center of DE cover 

 55°C)

An air flow with a velocity of more than 1.0 m/s is required in an environment of 45°C. (Center of DE cover 

 55°C)

MAM series... 

An air flow with a velocity of more than 0.6 m/s is required in an environment of 30°C. (Center of DE cover 

 55°C)

(at 250 IOPS)

An air flow with a velocity of more than 0.9 m/s is required in an environment of 35°C. (Center of DE cover 

 55°C)

An air flow with a velocity of more than 1.3 m/s is required in an environment of 40°C. (Center of DE cover 

 55°C)

An air flow with a velocity of more than 1.9 m/s is required in an environment of 45°C. (Center of DE cover 

 55°C)

4. TERMINATION–

A terminating resistor should be installed externally at both ends of the SCSI bus.

5.  TERMINATION  POWER–

TRMPWR  must  be  supplied  to  the  terminating  resistor  for  correct  operation.    This  can  be  supplied  from

either  the  drive,  except  for  MC  model  or  the  SCSI  bus.    If  only  MC  model  drives  are  connected  to  the  SCCI  bus,  TRMPWR  should  be
supplied externally.

6. ATTACHING THE CABLES–

To avoid possible damage to the drive, make sure the direction of the connector matches.

CAUTION:

Warranty may be avoided if damage to the connector is caused by wrong insertion.

Handling

1. Never

 drop.  Handle with care.

2. Never

 move the disk drive while the disks are spinning.  This is when the drive is powered on and also immediately after power off.  Refer

to the Start/Stop specification for your drive.

3. Always

 turn off the power before connecting or disconnecting the interface cable.  The same applies to changing any of the switches or

terminal settings except if the Write protect switch is present on MP model drives.

4. Never

 place the drive in the vicinity of strong magnetic fields such as monitors, televisions, or loudspeakers.

5. Never

 use any cleaning agents or liquids on the drive.

6. Always

 use an antistatic mat and wrist strap when handling the drive.  Hold the drive by the Base casting and never touch the components

on the PCA.

7. Never

 remove any labels from the drive and do not deface them in any way; these labels are part of the disk drive design.

8. Never

 open the disk enclosure for any reason.  There are no serviceable parts inside.  This will also invalidate any warranty.

9. Always

 pay close attention to the mounting specifications such as sway space and cooling.  If the temperature difference between storage

location and installation locations is more than 10°C, leave the drive in the new location for at least two hours for Temperature acclimation.
This minimises any risk of condensation forming on the drive.

The Drive needs NO preventative or periodic maintenance during its life time if properly used in the correct environment.

MAN3735, MAN3367, MAN3184 SERIES
MAM3367, MAM3184 SERIES
DISK DRIVES INSTALLATION GUIDE

FUJITSU LIMITED

Storage Products Group

4-1-1 Kamikodanaka, Nakahara-ku, Kawasaki 211-8588, Kanagawa-ken, Japan

Copyright © 2001 FUJITSU LIMITED

JAPAN

http://www.jp.fujitsu.com/