Mounting
Proline Promass E TB2 HART
20
Hauser
►
Ensure the system pressure is sufficiently high to prevent cavitation and outgassing.
For this reason, the following mounting locations are recommended:
A0013935
å
6
Downstream from pumps (no danger of vacuum)
A0013936
å
7
At the lowest point in a vertical pipe
Thermal insulation
Some fluids require suitable measures to reduce the heat convection from the sensor to the
transmitter. A wide range of materials can be used to provide the required thermal insulation.
NOTICE
Electronics overheating on account of thermal insulation!
►
Observe maximum permitted insulation height of the transmitter neck so that the transmitter
head is completely free.
£
20(0.79)
mm (in)
A0013937
Heating
NOTICE
Electronics can overheat due to elevated ambient temperature!
►
Observe maximum permitted ambient temperature for the transmitter (
►
Depending on the fluid temperature, take the device orientation requirements into account
(