Proline Promass E TB2 HART
Technical data
Hauser
105
DN 50
DN 40
DN 25
DN 8
10000
1000
100
10
1
0.1
0.001
0.01
0.1
1
10
100
1000
DN 15
[mbar]
[t/h]
A0013674
å
21
Pressure loss diagram for water
Pressure loss in US units
Pressure loss depends on the fluid properties and the nominal diameter.
18.10 Mechanical construction
Design, dimensions
For the dimensions and installation lengths of the device, see the "Technical Information"
document, "Mechanical construction" section
Rupture disk (optional)
Rupture disks cannot be combined with the separately available heating jacket (
Weight
Weight in SI units
Compact version
All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [lb]
DN
[mm]
Weight [kg]
With transmitter housing GT20,
aluminum coating
With transmitter housing GT18
1.4404/316L
8
6
8.5
15
6.5
9
25
8
10.5
40
13
15.5
50
22
24.5
Weight in US units
Compact version
All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [lb]