Proline Promass E TB2 HART
Technical data
Hauser
107
With transmitter housing GT18 1.4404/316L
Electrical connection
Type of protection
Material
Cable gland M20 × 1.5
• Non-Ex
• Ex ia
• Ex ic
• Ex nA
• Ex t
Stainless steel 1.4404
Thread G ½"
via adapter
For non-Ex and Ex
(except for CSA Ex d/XP)
Stainless steel 1.4404/316L
Thread ½" NPT
via adapter
For non-Ex and Ex
Thread M20 × 1.5
Ex d
Material load diagrams
An overview of the material load diagrams (pressure/temperature diagrams) for the process
connections is provided in the "Technical Information" document.
Process connections
• Flanges according to EN 1092-1 (DIN 2501), ASME B16.5 and JIS B2220
• VCO connections
• Sanitary connections
– Tri-Clamp
– Threaded hygienic connection: DIN 11851, SMS 1145, ISO 2853, DIN 11864-1 Form A
– DIN 11864-2 Form A (flat flange with groove)
For information on the materials of the process connections (
18.11 Human interface
Local display SD02
Display elements
• 4-line display
• Format for displaying measured values and status variables can be individually configured
• Permitted ambient temperature for the display: –20 to +60
°
C (–4 to +140
°
F)
The readability of the display may be impaired at temperatures outside the temperature range.
Operating elements
• Local operation with 3 push buttons ( , ,
E
)
• Operating elements also accessible in various hazardous areas
Additional functionality
The display module offers:
• Data backup function
The device configuration can be saved in the display module.
• Data comparison function
The device configuration saved in the display module can be compared to the current device
configuration.
• Data transfer function
The transmitter configuration can be transmitted to another device using the display module.