d) Bad spark plug
Without the proper ignition, it will be impossible to get the motor up and running. For this
reason, check the spark plug. (Read §”11.3.5
Checking and/or changing the
spark plug” on page 52)
e) Low on oil
The motor’s crankcase is filled with motor oil to lubricate and cool the pistons. Lack of oil can
lead to increased wear of the motor. To protect the motor the machine has been equipped
with a control switch that will disengage the motor if the machine is low on oil. Check the oil
level and refuel as necessary (read “11.3.3
Checking the oil level of the motor.” on
page 49)
9.8.2 Motor shuts off whilst in use
If the motor suddenly shuts off during operation, this could be the result of a number of factors:
a) No petrol
b) Lack of oil in the motor
c) Machine is on a slope
d) Technical defect
Caution:
Before examining possible reasons for the fault, make sure the ON/OFF switch
for the motor is turned to the OFF position.
Take the following steps to restart the machine in case of one of the following:
a) No petrol
Might you become so absorbed in your work that you fail to realise from the indicator arrow that
the machine is running on empty, then it could suddenly turn off. In this case, refuel the tank
(read § “9.4.2 Refuelling” on page 28)
Let the starter motor run for a while after refuelling. Close the throttle (choke) - the petrol will
now be sucked into the line. The motor will start running as soon as the carburettor has filled.
b) Lack of oil in the motor
Also read “9.8.1 The motor fails to start after idle periods” on page 37
c) Machine is on a slope
Whilst working on a slope in the lengthwise direction, the motor may suddenly stop. This is
caused by the oil alarm which works on the basis of level measurement; it detects a false oil level
when the machine is in a slanted position. This is enough reason for the system to switch off the
motor.
The solution is to wait a few moments before restarting the motor. The problem will return if you