INSTALLATION
3
The generated destructive torque depends on the presence of a torque reduction mechanism that
can be built into the flange, according to the pump model and flange type. This mechanism, shown in
Figure 30, is designed to absorb energy and also buffer the destructive torque.
There are two installation methods for the pump, as shown in Figure 31. Make sure to secure the
inlet port flange of the pump with the recommended bolts, as described in Figure 31, according to the
installation method used.
Note that special washers will be required if the pump includes the inlet torque reduction mechanism.
The washer shape is shown in Figure 30.
CAUTION
Install the flange securing bolts in the proper position with the special square washer shown in
Figure 30. Failure to do so may cause abnormal operation of the torque reduction mechanism and
damage the pump.
CAUTION
When any internal abnormality/error results in high rotational torque, causing the torque reduction
mechanism to operate, the pump may rotate a maximum of 5 degrees around the rotor rotation at
axis.
Содержание STP Series
Страница 22: ...STP iXA2205 Series Turbomolecular Pump Nov 10 12 Issue 1 h INTRODUCTION 1 This page intentionally blank ...
Страница 74: ...STP iXA2205 Series Turbomolecular Pump Nov 10 64 Issue 1 h INSTALLATION 3 This page intentionally blank ...
Страница 95: ...STP iXA2205 Series Turbomolecular Pump Nov 10 85 Issue 1 h 4 OPERATION Figure 55 X2 REMOTE output signal pins ...
Страница 98: ...STP iXA2205 Series Turbomolecular Pump Nov 10 88 Issue 1 h 4 OPERATION This page intentionally blank ...
Страница 172: ...STP iXA2205 Series Turbomolecular Pump Nov 10 162 Issue 1 h MAINTENANCE AND INSPECTION 8 This page intentionally blank ...