STP-iXA2205 Series Turbomolecular Pump
Nov. 10
37
Issue 1-h
INSTALLATION
3
3.4
How to install the STP pump
Install the STP pump to the vacuum equipment as shown in Figure 26 and Figure 27.
WARNING
An appropriate enclosure or a barrier which cannot be removed without using a tool
should be provided to prevent an operator from accessing the connection cables
between the STP pump and its connectors provided.
WARNING
When installing the STP pump and connecting/disconnecting cables, always power
off the primary power (switch the MAIN POWER to "OFF") and isolate
(Lockout/Tagout) the electrical energy source, water and gas, and other energy
sources on the vacuum equipment. Failure to do so may result in the inadvertent
rotation of the STP pump which may result in an accident, an electric shock or
damage to equipment.
Moreover, an accident caused by water leaks or gas leak may occur.
CAUTION
Use a lifter or the like when installing the STP pump to the vacuum equipment. Failure to do so
might hurt your back or cause injuries due to occurrence of an accident such as fall.
A supportive device such as lifter to installing the STP pump should withstand the load of five times
or more the weight of the STP pump.
*1
The equipment and part within the parentheses must be prepared by the customer.
Figure 26 - Installation of the STP pump to the vacuum equipment (STP-iXA2205C[V])
:
&% 176276
:
#% 219'4
2'
.
0
:
*'#6'4
/#+0 219'4
10
1((
To vacuum equipment
control circuit
Inlet port
(Vacuum equipment)
*1
Inlet port flange
(Backing -pump;
dry pump, and other)
*1
Outlet port flange
(Vacuum valve)
*1
To power supply
AC power cable
Remote operation cable
DC cable
Power unit
Содержание STP Series
Страница 22: ...STP iXA2205 Series Turbomolecular Pump Nov 10 12 Issue 1 h INTRODUCTION 1 This page intentionally blank ...
Страница 74: ...STP iXA2205 Series Turbomolecular Pump Nov 10 64 Issue 1 h INSTALLATION 3 This page intentionally blank ...
Страница 95: ...STP iXA2205 Series Turbomolecular Pump Nov 10 85 Issue 1 h 4 OPERATION Figure 55 X2 REMOTE output signal pins ...
Страница 98: ...STP iXA2205 Series Turbomolecular Pump Nov 10 88 Issue 1 h 4 OPERATION This page intentionally blank ...
Страница 172: ...STP iXA2205 Series Turbomolecular Pump Nov 10 162 Issue 1 h MAINTENANCE AND INSPECTION 8 This page intentionally blank ...