![Edwards STP Series Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/edwards/stp-series/stp-series_instruction-manual_2366164157.webp)
STP-iXA2205 Series Turbomolecular Pump
Nov. 10
147
Issue 1-h
7
SAFETY
FUNCTIONS
7.4
WARNING function setting
The WARNING functions can be set to Enable or Disable. Set to "ENABLE" when using the
WARNING function. Set to "DISABLE" to release each WARNING function after the WARNING is
detected.
A setting value of the "Pump Run Time Over" and "Pump Overload" are adjustable. The WARNING
detection can be released by setting the value larger than pump running hours after "Pump Run Time
Over" is detected. Also, the WARNING detection can be released by powering off the pump after
"Pump Overload" is detected.
See Table 43 and Table 44 for the default setting. The setting can be changed via serial
communication, the STP-Link (optional accessory) or the display unit iDT-001 (optional accessory).
WARNING function
Default setting
User setting
User setting
change (threshold)
Second Damage Limit
(Failure detection)
Enable
Enable
Disable
Second Damage Limit
(Warning detection)
Enable
Disable
Disable
First Damage Limit
Enable
Enable
Disable
Pump Run Time Over
Disable
Enable
Enable
Pump Overload
Disable
Enable
Enable
Imbalance
Enable
Enable
Disable
Table 43 - Default setting of WARNING function
WARNING function
Factory setting
(threshold)
Variable range
User setting
change (threshold)
Pump Run Time Over
0 hour
0 to 100,000
hours
It can be set in units of 100
hour. 0 is not counted.
Pump Overload
Motor
current
100.0 % 0 to 100.0 %
The ratio (%) to the rated
current value. Smaller
value has high possibility to
get "WARNING".
Rotational
speed
0.0 %
0 to 100.0 %
The rate (%) to the rated
speed value. Larger value
has high possibility to get
"WARNING".
Table 44 - Factory Setting and Variable Range
Note: Refer to Section 5, "Serial Communication Protocol", STP-Link, or the display unit iDT-001
Instruction Manuals for the setting methods.
Содержание STP Series
Страница 22: ...STP iXA2205 Series Turbomolecular Pump Nov 10 12 Issue 1 h INTRODUCTION 1 This page intentionally blank ...
Страница 74: ...STP iXA2205 Series Turbomolecular Pump Nov 10 64 Issue 1 h INSTALLATION 3 This page intentionally blank ...
Страница 95: ...STP iXA2205 Series Turbomolecular Pump Nov 10 85 Issue 1 h 4 OPERATION Figure 55 X2 REMOTE output signal pins ...
Страница 98: ...STP iXA2205 Series Turbomolecular Pump Nov 10 88 Issue 1 h 4 OPERATION This page intentionally blank ...
Страница 172: ...STP iXA2205 Series Turbomolecular Pump Nov 10 162 Issue 1 h MAINTENANCE AND INSPECTION 8 This page intentionally blank ...