STP-iXA2205 Series Turbomolecular Pump
Nov. 10
35
Issue 1-h
INSTALLATION
3
3.3.3 Name and function of the power unit
Figure 24 shows the front panel of the power unit.
When performing the insulation test on your equipment, refer to the precautions described in Section
3.1.4, "Insulation test".
1 "DC OUTPUT" connector (X12)
3 "HEATER" connector (X13)
2 "AC POWER" connector (X11)
4 "MAIN POWER" breaker
Figure 24 - Power unit (connector panel)
WARNING
A hazardous live voltage may exist at the connectors that are marked with the
warning sign
. DO NOT touch the connecter. Doing so may result in electric
shock. When connecting/disconnecting the connecter, always power off the primary
power (switch the MAIN POWER to "OFF") and isolate (Lockout/Tagout) the
electrical energy source, water and gas, and other energy sources on the vacuum
equipment.
Item
Description
Function
1
"DC OUTPUT" connector
(X12)
For the DC cable to connect the STP pump
Outputs 96V DC
Includes serial communication pins for the STP pump
2
"AC POWER" connector
(X11)
AC input inlet (240 Va.c. maximum)
For the AC power cable
Input voltage range is between 200 to 240V AC (50/60Hz)
3
"HEATER" connector (X13) Connect the TMS heater cable before operating the TMS unit.
In the case of waterproofing specification, this connector is not
equipped (240 Va.c. maximum). A blank plate is attached.
4
"MAIN POWER" breaker
Main power circuit breaker
NEVER stop the power supply to the STP pump while the STP
pump is in rotation. When switching ON the control unit
without connecting the DC cable, the breaker will trip.
Table 5 - Power unit connector panel connection
1
2
3
4
Содержание STP Series
Страница 22: ...STP iXA2205 Series Turbomolecular Pump Nov 10 12 Issue 1 h INTRODUCTION 1 This page intentionally blank ...
Страница 74: ...STP iXA2205 Series Turbomolecular Pump Nov 10 64 Issue 1 h INSTALLATION 3 This page intentionally blank ...
Страница 95: ...STP iXA2205 Series Turbomolecular Pump Nov 10 85 Issue 1 h 4 OPERATION Figure 55 X2 REMOTE output signal pins ...
Страница 98: ...STP iXA2205 Series Turbomolecular Pump Nov 10 88 Issue 1 h 4 OPERATION This page intentionally blank ...
Страница 172: ...STP iXA2205 Series Turbomolecular Pump Nov 10 162 Issue 1 h MAINTENANCE AND INSPECTION 8 This page intentionally blank ...