![Edwards STP Series Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/edwards/stp-series/stp-series_instruction-manual_2366164109.webp)
STP-iXA2205 Series Turbomolecular Pump
Nov. 10
99
Issue 1-h
5
SERIAL
COMMUNICATION
PROTOCOL
Then the preceding SIM->PC character is "Ack", the instructed control command is executed and the
SIM returns the following response.
PC->SIM
Ack or Nak
SIM->PC Stx 0
0
1
# or !
Etx LRC
The PC transmits "Ack" or "Nak"; then transmits the next command if necessary.
Transmission frame when data is transmitted to two blocks (message is more than 256 characters
and less than 512 characters):
Designate the control command (the 1st block) on the PC
PC->SIM Stx 0
0
1 Sp CHR C
1
C
253
Etb LRC
SIM->PC
Ack or Nak
Next, the preceding SIM->PC character is "Ack", the PC continues instructing the control command
(the 2nd block).
PC->SIM Stx 0
0
2 C
254
C
n
Etx LRC
SIM->PC
Ack or Nak
Always assign less than 510 characters (n< 510) to the parameter so that the message is less than
512 characters.
Then the preceding SIM->PC character is "Ack", the instructed control command is executed and the
SIM returns the following response.
PC->SIM
Ack or Nak
SIM->PC Stx 0
0
1
# or !
Etx LRC
The PC transmits "Ack" or "Nak"; then transmits the next command if necessary.
5.3.4 Query command (in the RS232/RS485 single point connection)
A query command is used to read the pump operation state and setting values. The first character of
the query command in the RS232/RS485 single point connection is "?"(HEX code "3F"), and
succeeding characters are ASCII characters corresponding to the respective function code and
parameter.
?
CHR
C
1
C
2
C
n
CHR: Function code character, C
1
to C
n
: Parameter
Содержание STP Series
Страница 22: ...STP iXA2205 Series Turbomolecular Pump Nov 10 12 Issue 1 h INTRODUCTION 1 This page intentionally blank ...
Страница 74: ...STP iXA2205 Series Turbomolecular Pump Nov 10 64 Issue 1 h INSTALLATION 3 This page intentionally blank ...
Страница 95: ...STP iXA2205 Series Turbomolecular Pump Nov 10 85 Issue 1 h 4 OPERATION Figure 55 X2 REMOTE output signal pins ...
Страница 98: ...STP iXA2205 Series Turbomolecular Pump Nov 10 88 Issue 1 h 4 OPERATION This page intentionally blank ...
Страница 172: ...STP iXA2205 Series Turbomolecular Pump Nov 10 162 Issue 1 h MAINTENANCE AND INSPECTION 8 This page intentionally blank ...