SAFETY
FUNCTIONS
1 cycle
Imbalance
(1 flash in orange)
OFF
㸣
Warning detection
"FAILURE" LED indication
X2 REMOTE output
ON
Pump Run Time Over
Pump Overload
(2 flashes in orange)
First Damage Limit
Second Damage Limit
(3 flashes in orange)
Corresponding to
warning type
OFF
OFF
ON
ON
Close
Open
WARNING N.O OUT
between (6)–(24)
WARNING N.C OUT
(6)–(25)
Open
Close
Figure 61 - WARNING output
Note: The WARNING detection cannot be reset by the "RESET" operation.
See Section 7.4, "WARNING function setting" for the releasing the WARNING detection.
The STP pump can operate even when the WARNING is detected.