Parameters of BT01 function block:
Source range:
>I1 MB15
Destination range:
>I2 64
Number of bytes:
>NO
4
Marker MB01: 1
After a rising edge from 0 to 1 at coil BT01T_ the content of
MB15 to MB18 is copied to the marker bytes MB65 to MB68.
Example:
Copying of marker blocks, definition of a marker range in a
different format.
The value of marker byte MD60 to MD62 is to be copied to
MW40 to MW45.
Parameters of BT01 function block:
Source range:
>I1 MD60
Destination range:
>I2 MW40
Number of bytes:
>NO 12
J
Destination range: Constant 64:
Marker MB01 plus Offset: 1 + 64 = 65
J
MB65.
Source range
Value of source
marker range
(decimal)
Destination
range
Value of
destination
marker range
(decimal)
MB15
68
MB65
68
MB16
189
MB66
189
MB17
203
MB67
203
MB18
3
MB68
3
J
The transfer is in byte format. 12 bytes are to be copied. The
range MD60 to MD62 is 12 bytes. This is copied to the
range MW40 to MW45.