Introduction to COM-LINK
For more information visit:
www.EatonElectrical.com
MN05013005E
353
Activating COM-LINK
COM-LINK must be activated in order for it to function.
Factory setting: not active
The tick on the COM-LINK menu item indicates that COM-
LINK is active.
Remote markers, COM-LINK data exchange range
Select the REMOTE MARKER... menu option. Here you can
determine, select and modify the data exchange range.
In the example the READ range was selected with the marker
double words MD11 to MD15.
The WRITE range consists of the marker double words MD16
to MD18.
The entire data exchange range available is the marker range
MD01 to MD20 of the remote station. The active station
accesses these markers with 1MD*. The * indicates the
number of the marker concerned.
The smallest possible unit for defining a marker range is an
MD marker double word.
Example:
The read range of the active station is 1MD02.
The write range of the active station is 1MD03.
The read range of the remote station is therefore MD03.
The write range of the remote station is MD02.
BAUDRATE:19200B
COM-LINK å
REMOTE MARKER...
J
The REMOTE MARKER.. menu only opens if a tick is
displayed next to COM-LINK.
READ:
1MD11 Ç 1MD015
WRITE:
1MD16 Ç 1MD18