For more information visit:
www.EatonElectrical.com
Visualization with EZD
MN05013005E
328
Screen 1:
The first screen contains four message text elements. These
are activated in succession via the outputs Q1 to Q4 and
appear in the display.
Screen 2:
The second screen contains a message text element with two
message texts. The message texts are activated via counter
values 1 and 4. A default text “default” has also been defined.
• Status value 1. “Error” message text
• Status value 2 and 3: “default” as default text
• Status value 4. “RESTART” message text
If the status value of C01 is 1, the message “error” flashes as
the function block parameter FB has been set in the Display
change area in the Display change tab. The function block
parameter switches if the SL value (lower switch threshold) of
the counter is reached (
J
EZSoft function block editor,
counter C01).
Figure 179: Message text with default text
Start Machine 1
Start Machine 2
Start Machine 3
Start Machine 4
Error
default: