Screen overview
For more information visit:
www.EatonElectrical.com
MN05013005E
313
Number range/format tab
The Number range/format tab is used for defining the
following:
• Value range,
• Unit of measure,
• Scaling range and
• Input format.
The display of the value sign can be forced.
Visibility tab
The Visibility tab enables you to make the screen element
invisible via an associated variable.
Operability tab
In the Operability tab, select the associated variable for
disabling the entry element.
Example program – value entry
The program consists of seven screens that can be selected
using the Cursor buttons
Í
and
Ú
. The screen change was
defined in the Button editor (
Page 331). When the EZD is in RUN mode, you can change
values that are processed in the program by using the Cursor
buttons
ú
í
Í
Ú
. The EZD shows the actual values in the
display.
In order to change values, the EZD must first switch to
Selection mode. In Selection mode you can select the value
entry element containing the values you wish to change.
X
Press
OK
to switch the EZD to Selection mode. Use
ESC
to exit Selection mode.
The selected value entry element will flash. If several value
entry elements are present, use the Cursor buttons
ú
í
Í
Ú
to
select the required element (
J
Screen 7).
X
Press the
OK
button to move from Selection mode to Entry
mode.