For more information visit:
www.EatonElectrical.com
Programming wiring
MN05013005E
130
The following rules apply if you want to use selective binary
operands (contacts) from the markers MD, MW, MB:
Table 9:
Composition of the markers
Markers
Analog operand
EZD
display
Number
Value
range
Access type
r = Read
w = Write
Marker 32 bit
1MD
01
…
20
32 bit
r, w
Marker 16 bit
1MW
01
…
40
16 bit
r, w
Marker 8 bit
1MB
01
…
80
8 bit
r, w
Marker 1 bit
1M
1
…
96
1 bit
r, w
Analog inputs
basic unit
1IA X
X=01
…
04
10 bit
r
Analog output
1QA X
X=01
10 bit
r
Applies to
MD, MW,
MB, M
Left = most
significant bit, byte,
word
Right = least
significant bit, byte,
word
32 bit
MD1
16 bit
MW2
MW1
8 bit
MB4
MB3
MB2
MB1
1 bit
M32 to M25
M24 to M17
M16 to M9
M8 to M1
32 bit
MD2
16 bit
MW4
MW3
8 bit
MB8
MB7
MB6
MB5
1 bit
M64 to M57
M56 to M49
M48 to M41
M40 to M33
32 bit
MD3
16 bit
MW6
MW5
8 bit
MB12
MB11
MB10
MB9
1 bit
M96 to M89
M88 to M81
M80 to M73
M72 to M65
32 bit
MD4