Technical data
For more information visit:
www.EatonElectrical.com
MN05013005E
413
Electromagnetic compatibility (EMC)
Electrostatic discharge (ESD),
(IEC/EN 61000-4-2, severity level 3)
Air discharge
kV
8
Contact discharge
kV
6
Electromagnetic fields (RFI),
(IEC/EN 61000-4-3)
V/m
10
Radio interference suppression (EN 55011, IEC 61000-6-1, 2, 3, 4),
limit class
B
Burst (IEC/EN 61000-4-4, severity level 3)
Power cables
kV
2
Signal cables
kV
2
High energy pulses (Surge) EZD
(IEC/EN 61000-4-5, severity level 2), power cable
symmetrical
kV
0.5
Line-conducted interference (IEC/EN 61000-4-6)
V
10
Dielectric strength
Measurement of the air clearance and creepage distance
EN 50178, UL 508,
CSA C22.2, No 142
Dielectric strength
EN 50178
Overvoltage category/degree of pollution
II/2
Tools and cable cross-sections
Solid, minimum to maximum
mm
2
0.2 to 4
AWG
24 to 12
Flexible with ferrule, minimum to maximum
mm
2
0.2 to 2.5
AWG
24 to 12
Slot-head screwdriver, width
mm
3.5
×
0.5
inch
0.14
×
0.02