JA-16J One-way four-button keyfob 

JA-16J One-way four button keyfob 

1 / 2 

MMJ21101 

The JA-16J is a component of the 

JA-10

 system. It uses one way 

communication. It is designed to remotely control a security system, 

various appliances (using PG  programmable outputs PG) or to 

trigger panic alarms. The remote  is equipped with optical and 

acoustic indication. It checks its battery status and indicates when 

the battery is nearly discharged. 

Figure:

 1 – LED indication;  

A, B, C, D – buttons, see their functions according to table 1. 

Enrolling the remote control to a control 

panel 

There must be a JA-111R radio module installed in the control 

panel for the ability to work with a control panel. The remote can be 

enrolled to an arbitrary number of JA-10 systems and one pair of 

buttons can control multiple sections in the system (common 

control). It occupies one position in the system. 
1. Control panel has to be in service mode. 
2. Basic procedure:

a. Go to the 

N-Link

  software, select the required position

in the 

Devices

 tab and launch 

enrollment

 mode.

b. For  the  transmission of an enrollment signal press and hold 

buttons (A+B) simultaneously for at least 3 s (within this time

the red LED flashes rapidly).

c. After 3 s the enrollment signal is sent and confirmed by one 

long  LED flash. Release both buttons and close enrollment 

mode. 

To set the keyfob to comply with security 

grade 2 or other requirements use  the 

N-Link SW, open Parameters tab and select

corresponding option from “System

Profiles”(See the JA-10 control panel

installation manual).

Notes: 

Enrolling the remote control to the system is possible by

entering the production code via N-Link  software.

The production code is  on the sticker with  a  bar code glued

onto  the battery holder inside the remote. All digits in the

production code are required (1400-00-0000-0001).

If you want to remove the remote control  from the system

(for instance when someone has  lost it), erase it from the

particular address of the control panel.

Setting the properties 

Perform settings using 

N-Link

  software  – 

Devices

  tab. Click 

on the JA-16J´s 

Internal settings

. Then a window appears 

automatically where you can set the following parameters: 

Functions of the buttons:

 set a particular function for the  pair 

of buttons A-B or C-D (setting / unsetting typically, ON / OFF 

switching  of some appliance, etc.) or a  function for each  single 

button A, B, C, D (gate opening, garage door opening, etc.)  and 

a double press of the A+B or C+D buttons, which can trigger silent 

panic. For an option overview see table 1. 

Reaction for single buttons 

 

 / 

 / 

 (A/B/C/D)

 

Reaction for pressing 

simultaneously 

+

/

 

+

 

(A+B/C+D)

None (button not used)

Change PG state

Silent panic *)

Audible panic *)

Health troubles

Silent panic

Reaction for pair of buttons 

-

/

 

 

(A-B/C-D) 

Unset / Set

Unset / Partially set

Unset / Partially set / Set

Unset/Set with confirmation

Unset/Set partially with confirmation

Unset/Set partially/Set with confirmation

PG OFF / PG ON

Table: 1. Button function options overview 

For each function selected for a remote control button it is 

necessary to select the appropriate PG or sections to be controlled 

or from which reports should be sent (panic, etc.). For the common 

control of multiple sections it 

is not recommended

  to operate 

a common section, but to select the desired section in the remote 

control internal settings. 

Notes: 

*)   The reactions of the buttons which are not supported when 

the system is configured to comply with security grade 2. 

The option “

Do not set with active zone“, 

doesn´t allow the

system to be set using a remote control (keyfob) when any

zone with  an 

Instant

  reaction is active. To set the system all

zones / detectors have to be in standby

Pressing both triggers a silent panic

: According to the settings 

control panel reacts to double pressing of those buttons by 

triggering silent panic alarm from the section where the keyfob has 

been enrolled. When the keyfob is locked down its necessary to 

perfrom doubles press 2x per 1 sec. Confirmed by flash of red LED 

on the keyfob. 

Assign  to  user:

  Takes  over  user’s access privileges for the 

sections and time limited access according to the specific user. 

Locking the keyfob 

The remote control buttons can be locked (blocked) against 

accidental pressing. Locking is disabled by default, pressing any 

button triggers its function immediately. If the buttons are locked,  

a control panel command is sent when a button is pressed 2x 

quickly (2x per 1 s) it is also valid for the panic function. 

The 

lock can be activated 

by  pressing and holding  the pair 

of buttons (A+B) at the same time. After pressing both buttons the 

red LED (1) flashes 1x and subsequently after 3 s the red LED 

starts flashing quickly, during LED flashing release button B and 

then press it again. Activation of the lock function is performed and 

confirmed  by double flashes of the red LED and a double beep. 

After this confirmation release all buttons. 

The 

lock is deactivated

  by repeating the procedure above. 

Deactivation of locking is confirmed by one flash of the red LED 

and one beep. 

Caution:  When a reaction for pressing buttons (A+B) 

simultaneously is set  (for example a panic alarm or garage 

door control), it is necessary to mind that the action 

is performed first. 

Acoustic indication 

Acoustic indication can be completely disabled. The default 

is enabled. When any button is pressed it is followed by a  short 

acoustic signal according to the table 2. 

The 

acoustic indication

 can be disabled by simultaneous pressing 

and holding  the pair of buttons (A+B) until the red LED (1) starts 

flashing briefly for the second time, usually in 6 s. When the red LED (1) 

flashes a second time release the button (B) and press it again. The 

acoustic indication is then disabled and confirmed by flashes of the red 

LED and a one beep. After this confirmation release all buttons. 

The 

acoustic indication

  can be enabled by repeating 

the procedure above. Activation is confirmed by a double flash 

of the red LED and a double beep. 

Caution: When a reaction for pressing buttons (A+B) simulta-

neously is set (for example a panic alarm or garage door 

control), it is necessary to mind that the action is performed 

first. 