Troubleshooting the Power Supply
Troubleshooting if the system unit has no power
If the system unit has no power,
1.
Check the power supply LED. If the LED does not glow
green, make sure the power is on and the power cord is
connected to the back of the system unit and to a power
outlet.
2.
If the problem persists, make sure the red 5-volt and black
ground system module power cords are connected properly.
a.
Turn off the system unit power.
b.
Disconnect the system unit power cord.
c.
Remove the system unit cover and front cover plate.
Refer to Chapter 2 for directions.
d.
Make sure the 5-volt system module power cord
and black ground cord are in the correct connectors.
Figure 5-10 shows the correct cord connections.
e.
Replace the system unit cover and front cover plate.
3.
If the system unit still has no power, replace the power
supply. Refer to the following section for directions.