Partial Write Test
The partial write test writes to a specific memory address and
then checks whether the written values are correct. To run the
partial write test, type t 7/misc/wbpart and press Return.
Partial write test error messages
Partial write test error messages have the form
?TFL: 7/misc/wbpart (code)
?TFL 7/misc/wbpart indicates that the partial write test
reported an error.
code represents some code that identifies which portion of
the test failed.
Table D-16 lists the error codes used in partial write test error
messages.
Table D-16.
Partial Write Test Error Codes
Error Code
Meaning
1
Pattern that was read showed mismatch on word access.
2
Byte 0 failed partial byte write.
3
Byte 1 failed partial byte write.
4
Byte 2 failed partial byte write.
5
Byte 3 failed partial byte write.
6
Halfword 0 failed partial halfword write.
7
Halfword 1 failed partial halfword write.
Test Commands and Messages
D–27
Содержание DECstation 5000 Model 100 Series
Страница 22: ...Up to seven drives Ethernet WSE2M001 ole hardware configurations ation DECsystem 5000 Model 200 Hardware 1 3...
Страница 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Страница 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Страница 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Страница 100: ...WSE2M051 power cord connections...
Страница 102: ...WSE2M045 power supply fan assembly connection...
Страница 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...