Partial Write Test
This test performs a read and write to a specific address, then
checks if the read and write values are the same. To run the
Partial Write test, type t f35 P1, where you replace P1 with the
memory address to which you want to write, and press Return.
Partial write test error messages
Table F-31 describes the parameters in partial write test
commands and error messages.
Table F-32 lists the error codes used in partial write test error
messages.
Table F-31.
Partial Write Test Parameters
Parameter
Description
P1
Memory address to which to write pattern
P2
Pattern read back from memory
Table F-32.
Partial Write Test Error Codes
Error Code
Meaning
1
Pattern that was read showed mismatch on word access.
2
Byte 0 failed partial byte write.
3
Byte 1 failed partial byte write.
4
Byte 2 failed partial byte write.
5
Byte 3 failed partial byte write.
6
Halfword 0 failed partial halfword write.
7
Halfword 1 failed partial halfword write.
F–26
Test Commands and Messages Produced by Version PDE3 ROM Chips
Содержание DECstation 5000 Model 100 Series
Страница 22: ...Up to seven drives Ethernet WSE2M001 ole hardware configurations ation DECsystem 5000 Model 200 Hardware 1 3...
Страница 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Страница 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Страница 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Страница 100: ...WSE2M051 power cord connections...
Страница 102: ...WSE2M045 power supply fan assembly connection...
Страница 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...