Mouse Test
The mouse test checks the mouse and its serial line controller
on the system module.
To run the mouse test, type t 7/misc/mouse [loopback] and
press Return.
When you type the mouse test command, use the optional
loopback parameter to specify whether the test should also
search for a mouse or mouse loopback connector.
Specify y to have the test search for a mouse loopback
connector.
Specify n to have the test search only for a mouse connector.
Mouse test error messages
Mouse test error messages have the form
?TFL: 7/misc/mouse (description)
?TFL 7/misc/mouse indicates that the mouse test reported
an error.
description represents additional information that describes
the failure.
Table D-15 lists the error descriptions found in mouse test error
messages.
Table D-15.
Mouse Test Error Descriptions
Error Description
Meaning
(missing?)
Mouse is missing or not operating properly.
(failed self-test: xx)
Mouse failed its self-test. xx represents the
mouse test result.
Test Commands and Messages
D–25