Error and status register error logs
Error and status register error logs record nonmemory errors.
This is a sample of the error log sections that are unique to
error and status register error logs.
----- ERROR & STATUS REGS -----
CAUSE
x80002000
EXCEPTION CODE EXTERNAL
INTERRUPT
HW INTERRUPT 3 PENDING
BRANCH DELAY SET
STATUS
x0000FE04
CURRENT INTERRUPT STATE DISABLED
CURRENT MODE KERNEL
PREVIOUS INTERRUPT STATE ENABLED
PREVIOUS MODE KERNEL
OLD INTERRUPT STATE DISABLED
OLD MODE KERNEL
SW INTERRUPT 1 ENABLED
HW INTERRUPT 0 ENABLED
HW INTERRUPT 1 ENABLED
HW INTERRUPT 2 ENABLED
HW INTERRUPT 3 ENABLED
HW INTERRUPT 4 ENABLED
HW INTERRUPT 5 ENABLED
CACHE STATE NORMAL
SP
xFFFFDC58
KN02 STAT REG
x05C20001
IO INT 0 PENDING
19,200 BAUD
8 MB MEM MODULE
ECC CMD x0
IO INT 1 ENABLED
IO INT 6 ENABLED
IO INT 7 ENABLED
NORMAL MODE
REFRESH ODD MEM MODULES
UNSECURE
ERROR ADDR REG
xE7B00000
CPU I/O WRITE TIMEOUT
PHYSICAL ERROR ADDR x1EC00000
Troubleshooting Tools
3–13
Содержание DECstation 5000 Model 100 Series
Страница 22: ...Up to seven drives Ethernet WSE2M001 ole hardware configurations ation DECsystem 5000 Model 200 Hardware 1 3...
Страница 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Страница 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Страница 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Страница 100: ...WSE2M051 power cord connections...
Страница 102: ...WSE2M045 power supply fan assembly connection...
Страница 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...