Serial Line Silo Alarm Test
The serial line silo alarm test checks the serial line controller’s
ability to generate a silo alarm interrupt.
To run this test, type t f42 P1 P2 and press Return.
Serial line silo alarm test error messages
Table F-4 describes the parameters in serial line silo alarm test
commands and error messages.
Table F-5 lists the error codes found in serial line silo alarm
error messages.
Table F-4.
Serial Line Silo Alarm Test Parameters
Parameter
Description
P1
Specifies the test’s loopback setting. Specify 0 for internal
loopback; specify 1 for external loopback.
P2
Specifies the serial line to be tested.
Specify 0 to test the keyboard.
Specify 1 to test the mouse.
Specify 2 to test the right communications line .
Specify 3 to test the left communications line.
P3
Actual value in register named in the subtest.
P4
Expected value in register named in the subtest.
Table F-5.
Serial Line Silo Alarm Test Error Codes
Error Code
Meaning
1
Silo alarm test failed.
2
Unexpected silo alarm interrupt occurred.
3
Silo alarm timeout error occurred.
4
No silo alarm interrupt occurred.
F–6
Test Commands and Messages Produced by Version PDE3 ROM Chips
Содержание DECstation 5000 Model 100 Series
Страница 22: ...Up to seven drives Ethernet WSE2M001 ole hardware configurations ation DECsystem 5000 Model 200 Hardware 1 3...
Страница 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Страница 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Страница 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Страница 100: ...WSE2M051 power cord connections...
Страница 102: ...WSE2M045 power supply fan assembly connection...
Страница 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...