Ethernet Tests
The following entries explain the purpose, test commands, and
error messages for each individual Ethernet test.
Registers Test
The registers test performs a read/write operation on the
Ethernet register. To run the registers test, type t x01, where x
represents the unit number of the Ethernet controller you want
to test, and press Return.
Registers test parameters and error codes
In registers test error messages, P1 indicates the last value
that was read from CSR0.
Table F-34 lists the error codes used in registers test error
messages.
Table F-34.
Registers Test Error Codes
Error Code
Description
1
First write to Ethernet CSRs failed.
2
Reading CSR values and comparing them to zero failed.
3
Comparing value in CSR1 to pattern of all ones failed.
4
Comparing value in CSR2 to pattern of all ones failed.
5
Test for bit leak from CSR2 to CSR1 failed.
6
Test for bit leak from CSR1 to CSR2 failed.
7
Immediate write/read test failed.
F–28
Test Commands and Messages Produced by Version PDE3 ROM Chips
Содержание DECstation 5000 Model 100 Series
Страница 22: ...Up to seven drives Ethernet WSE2M001 ole hardware configurations ation DECsystem 5000 Model 200 Hardware 1 3...
Страница 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Страница 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Страница 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Страница 100: ...WSE2M051 power cord connections...
Страница 102: ...WSE2M045 power supply fan assembly connection...
Страница 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...