![Danfoss FC 300 Скачать руководство пользователя страница 122](http://html1.mh-extra.com/html/danfoss/fc-300/fc-300_programming-manual_3466881122.webp)
34-07 PCD 7 Write to
MCO
34-08 PCD 8 Write to
MCO
34-09 PCD 9 Write to
MCO
34-10 PCD 10 Write to
MCO
Select the process write data for I/O Assembly Instances 101/151. Elements [2] and [3] of this array can be
selected. Elements [0] and [1] of the array are fixed.
10-12 Process Data Config Read
Option:
Function:
None
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
(Fixed)
16-04 Main Actual Val-
ue [Unit]
16-05 Main Actual Val-
ue (%) (Fixed)
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-16 Torque
16-17 Speed [RPM]
16-18 Motor Thermal
16-19 KTY Sensor
Temperature
16-21 Phase Angle
16-30 DC Link Voltage
16-32 BrakeEnergy/s
16-33 BrakeEnergy/2
min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-38 SL Control State
16-39 Controlcard
Temp.
16-50 External Refer-
ence
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Refer-
ence
16-60 Digital Input
16-61 Terminal 53
Switch Setting
2. How to Programme
FC 300 Programming Guide
122
MG.33.M3.02 - VLT
®
is a registered Danfoss trademark
2