Display Contrast Adjustment
Press [status] and [
▲
] for darker display
Press [status] and [
▼
] for brighter display
Most parameter set-ups can be changed immediately via the control panel, unless a password has been created via par. 0-60
Main Menu Password
or
via par. 0-65
Quick Menu Password
.
Indicator lights (LEDs):
If certain threshold values are exceeded, the alarm and/or warning LED lights up. A status and alarm text appear on the control panel.
The ON LED is activated when the frequency converter receives mains voltage or via a DC bus terminal or 24 V external supply. At the same time, the
back light is on.
•
Green LED/On: Control section is working.
•
Yellow LED/Warn.: Indicates a warning.
•
Flashing Red LED/Alarm: Indicates an alarm.
130BP040.10
LCP keys
The control keys are divided into functions. The keys below the display
and indicator lamps are used for parameter Set-up, including choice of
display indication during normal operation.
130BP045.10
[Status]
indicates the status of the frequency converter and/or the motor. You can choose between 3 different readouts by pressing the [Status] key:
5 line readouts, 4 line readouts or Smart Logic Control.
Use
[Status]
for selecting the mode of display or for changing back to Display mode from either the Quick Menu mode, the Main Menu mode or Alarm
mode. Also use the [Status] key to toggle single or double read-out mode.
[Quick Menu]
allows quick access to different Quick Menus such as:
-
My Personal Menu
-
Quick Set-up
-
Changes Made
-
Loggings
Use
[Quick Menu]
for programming the parameters belonging to the Quick Menu. It is possible to switch directly between Quick Menu mode and Main
Menu mode.
[Main Menu]
is used for programming all parameters.
It is possible to switch directly between Main Menu mode and Quick Menu mode.
Parameter shortcut can be carried out by pressing down the
[Main Menu]
key for 3 seconds. The parameter shortcut allows direct access to any
parameter.
[Alarm Log]
displays an Alarm list of the five latest alarms (numbered A1-A5). To obtain additional details about an alarm, use the arrow keys to
manoeuvre to the alarm number and press [OK]. You will now receive information about the condition of your frequency converter right before entering
the alarm mode.