4. Installation
4.3 Connection of Water Inlet Pipe
•
Take out water inlet pipe module (1), tee adapter (2), sealing pad (3) and filter
screen sealing pad (4) from the accessory foam boxes.
•
Place the filter screen sealing pad (4) at the connection end (5) of the water
inlet pipe modules, and connect it with the tee adapter.
•
Close the user’s water supply system source; remove the tap and switch
it over to the tap connector (6) of the water inlet pipe modules; and connect
the water inlet connector (7) of water inlet pipe to the user’s water supply
system.
•
Place the sealing pad ring (3) into the connector of the input end of water
inlet pipe (8); connect it to the water inlet connector (9) of slide stainer; and
screw it tightly to ensure that the pipeline is sealed.
The regulator (10) can adjust the size of the water flow. Before adjusting the water
pressure, first pull the blue control valve knob out and rotate it. The "+" direction
rotates to increase the water pressure and rotate in the "-" direction To reduce water
pressure. After adjustment, press the control valve knob to lock back.
Fig.7
图 2
7
6
8
9
5
1
3
2
4
4
Increase
Increase
Decrease
The
maximum
working
pressure
of
water
inlet
pipe
is
0.833Mpa
(8.5Kg/cm2,
and
higher
pressure
than
that
may
cause
the
leakage
or
damage
to
fluid
circuit
system.