SiBE18-821_C
Indoor Unit
Printed Circuit Board Connector Wiring Diagram
41
3.1.5 FTXS60/71GV1B
Connectors and
Other Parts
PCB (1): Control PCB
PCB (2): Signal Receiver PCB
PCB (3): Display PCB
PCB (4): INTELLIGENT EYE Sensor PCB
1) S1
Connector for DC fan motor
2) S21
Connector for centralized control (HA)
3) S25
Connector for INTELLIGENT EYE sensor PCB
4) S32
Connector for indoor heat exchanger thermistor
5) S41
Connector for swing motors
6) S46
Connector for display PCB
7) S47
Connector for signal receiver PCB
8) H1, H2, H3, FG Connector for terminal board
9) V1
Varistor
10) JA
Address setting jumper
∗
Refer to page 154 for detail.
JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
∗
Refer to page 157 for detail.
11) LED A
LED for service monitor (green)
12) FU1 (F1U)
Fuse (3.15 A, 250 V)
1) S48
Connector for control PCB
1) S49
Connector for control PCB
2) SW1
Forced operation ON/OFF button
3) LED1 (H1P)
LED for operation (green)
4) LED2 (H2P)
LED for timer (yellow)
5) LED3 (H3P)
LED for INTELLIGENT EYE (green)
6) RTH1 (R1T)
Room temperature thermistor
1) S36
Connector for control PCB
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...