![Daikin Super Multi Plus E-Series FTXG25EV1BW Скачать руководство пользователя страница 351](http://html1.mh-extra.com/html/daikin/super-multi-plus-e-series-ftxg25ev1bw/super-multi-plus-e-series-ftxg25ev1bw_service-manual_4705813351.webp)
SiBE18-821_C
Service Check Function
Troubleshooting
339
5. Press the TEMP
▲
or
▼
button
and change the figure until you hear the sound of “beep”.
6. Diagnose by the sound.
★
“pi” : The figure of the ten’s place does not accord with the error code.
★
“pi pi” : The figure of the ten’s place accords with the error code but the one’s not.
★
“beep” : The both figures of the ten’s and one’s place accord with the error code.
7. Determine the error code.
The figures indicated when you hear the “beep” sound are error code.
(Error codes and description
→
Refer to page 350, 351.)
8. Press the MODE button to exit from the diagnosis mode.
The display “
” means the trial operation mode.
(Refer to page 132 for trial operation.)
9. Press the ON/OFF button twice to return to the normal mode.
Note:
When the remote controller is left untouched for 60 seconds, it returns to the normal mode.
(R8383)
(R8384)
(R9659)
(R9660)
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...