SiBE18-821_C
Field Settings
Test Operation and Field Settings
155
G-Series, 60/71 Class
< Floor Standing Type>
1) Remove the front grille.
2) Lift the sensor PCB fixing plate and remove the front shield plate.
3) Disconnect the connectors [S1] [S41] [S42].
4) Remove the electric box (1 screw).
5) Pull out the indoor heat exchanger thermistor.
6) Remove the shield plate (8 tabs).
7) Cut the address jumper JA on the indoor unit PCB.
8) Cut the address jumper J4 in the remote controller.
(Refer to “Wireless remote controller”.)
G-Series, 20-50 Class
F-Series
ADDRESS
JA
ADDRESS
JA
EXIST
1
CUT
2
(R12216)
(R2872)
ADDRESS
ADDRESS
EXIST
CUT
ADDRESS
JC
JA
JB
ADDRESS:JA
EXIST
1
CUT
2
(R11735)
3) Connector [S42]
3) Connector [S41]
3) Connector [S1]
4) Remove the screw.
5) Indoor heat exchanger
thermistor
JA Address
EXIST
1
CUT
2
JA
JC
JB
2) Front shield plate
6) Shield plate
(R11692)
2) Sensor
PCB fixing
plate