Indoor Unit Control (RA Models)
Function
117
7.14 Other Functions
7.14.1 Hot-Start Function
In order to prevent the cold air blast that normally comes when heating operation is started, the
temperature of the indoor heat exchanger is detected, and either the airflow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat is turned ON.
7.14.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
7.14.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
Press this button once to start operation. Press once again to stop it.
This button is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
In the case of multi system operation, there are times when the unit does not activate with
this button.
ex. Wall mounted type G-series 20-50 class
7.14.4 Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air-Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter as a single highly effective filter. The filter traps microscopic particles, decompose odors
and even deactivates bacteria and viruses. It lasts for 3 years without replacement if washed
about once every 6 months.
7.14.5 Photocatalytic Deodorizing Filter
The photocatalytic deodorizing filter powerfully decomposes odor of tobacco, pet, etc. The
deodorizing power is regenerated simply by being exposed to the sunshine. It is recommended
to dry the filter in the sun for about 6 hours (after vacuuming the filter) every 6 months.
7.14.6 Air-Purifying Filter
The air-purifying filter collects tobacco smoke, pollen, etc. with electrostatic agency. This filter
includes a deodorizing active carbon filter that removes minute particles of odor. Replace the
air-purifying filter every 3 months.
Mode
Temperature setting
Airflow rate
AUTO
25°C
Automatic
(R8302)
ON/OFF button
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...