SiBE18-821_C
Indoor Unit Control (RA Models)
Function
111
7.10 HOME LEAVE Operation
Outline
HOME LEAVE operation is a function that allows you to record your favorite set temperature
and airflow rate. You can start your favorite operation mode simply by pressing the [HOME
LEAVE] button on the remote controller.
Detail
1. Start of Function
The function starts when the [HOME LEAVE] button is pressed in cooling mode, heating mode
(including POWERFUL operation), or while the operation is stopped. If this button is pressed in
POWERFUL operation, the POWERFUL operation is canceled and this function becomes
effective.
The [HOME LEAVE] button is ineffective in dry mode and fan mode.
2. Details of Function
A mark representing HOME LEAVE is indicated on the display of the remote controller. The
indoor unit is operated according to the set temperature and airflow rate for HOME LEAVE
which were pre-set in the memory of the remote controller.
The LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when the
operation is stopped.)
3. End of Function
The function ends when the [HOME LEAVE] button is pressed again during HOME LEAVE
operation or when the [POWERFUL] button is pressed.
Others
The set temperature and airflow rate are memorized in the remote controller. When the remote
controller is reset due to replacement of battery, it is necessary to set the temperature and
airflow rate again for HOME LEAVE operation.
<Cooling>
“HOME LEAVE operation”
set temp.
Normal operation
HOME LEAVE operation
Time
(R1366)
Stop
Normal operation
Start
Set temp.
<Heating>
“HOME LEAVE operation”
set temp.
HOME LEAVE operation
Normal operation
Normal operation
Set temp.
(R1367)
Time
Start
Stop
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...