SiBE18-821_C
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
Operation Manual
257
Operation manual
5
BRC1D528
Remote controller
4PW23717-1
4. Description of the operation modes
4
3
2
COOLING OPERATION
5
HEATING OPERATION
6
LIMIT OPERATION
&
7
LEAVE HOME
5. Operation
1 FAN ONLY OPERATION
In this mode, air only circulates without heating or
cooling.
DRY OPERATION
In this mode, the air humidity will be lowered with a
minimal temperature decrease.
The temperature and fan speed are controlled
automatically and cannot be controlled by the remote
controller.
Dry operation will not function if the room temperature
is too low.
AUTOMATIC OPERATION
In this mode, the controller will automatically switch
between heating and cooling as required by the
setpoint or limit temperature.
In this mode, cooling will be activated as required by
the setpoint or limit temperature.
In this mode, heating will be activated as required by
the setpoint or limit temperature.
Hot start (heat pump types only)
At the start of a heating operation, the indoor fan is
stopped until a certain indoor heat exchanger
temperature is reached and is displayed.
This prevents cold air from leaving the indoor unit.
Defrost (heat pump types only)
In heating operation, freezing of the outdoor heat
exchanger may occur. If so, the heating capacity of
the system lowers and the system goes into defrost
operation. The indoor unit fan stops and is
displayed. After maximum 10 minutes of defrost
operation, the system returns to heating operation
again.
Limit operation is an additional mode that enables to
keep the room temperature within certain limits. The
& i c o n s a r e d i s p l a y e d t o c o n f i r m t h e
activation of the limit operation.
LEAVE HOME is a feature that enables to keep the
room temperature above 10
°
C when the occupants
are out. This function will switch on heating if the
installation is switched off.
Manual operation
In manual operation, the user decides about the
settings of the installation. The last setting
remains active until the user changes it.
As the controller can be implemented for a wide
variety of installations and features, it might occur that
you select a function that is not available on your
installation; if this is the case, the message
will appear.
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...