110
Function
7.9
ECONO Operation
The "ECONO operation" reduces the maximum operating current and power consumption
during start-up etc..
This operation is particularly convenient for energy-saving-oriented users. It is also a major
bonus for those whose breaker capacities do not allow the use of multiple electrical devices and
air conditioners.
It is easily activated from the wireless remote controller by pushing the ECONO button.
When this function is activated, the maximum capacity decreases.
The remote controller can send the ECONO command when the unit is in cooling, heating,
dry, or automatic operation. This function can only be set when the unit is running. Pressing
the ON/OFF button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
When the ECONO command is valid, the input current is under reducing control.
ECONO Operation
(R9288)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Содержание Super Multi Plus E-Series FTXG25EV1BW
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...