Configuring and Managing Ports and VLANs
Configuring Port Operating Parameters
Autonegotiation is enabled by default on a switch’s 10/100 Ethernet ports.
You can configure the following port operating parameters:
• Speed
• Autonegotiation
• Port state
• PoE state
You also can toggle a port’s administrative state and PoE setting off and back on to reset
the port.
10/100 Ports—Autonegotiation and Port Speed
10/100 Ethernet ports use autonegotiation by default to determine the appropriate port
speed. Ports on the DWS-1008 switch support half-duplex and full-duplex operation.
To explicitly set the port speed of a 10/100 port, use the following command:
set port speed
port-list
{
10
|
100
|
auto
}
To set the port speed on ports 1, 3 through 6 to 10 Mbps, type the following command:
DWS-1008#
set port speed 1,3-6 10
Disabling or Reenabling a Port
All ports are enabled by default. To administratively disable a port, use the following
command:
set port
{
enable
|
disable
}
port-list
A port that is administratively disabled cannot send or receive packets. This command does
not affect the link state of the port.
Disabling or Reenabling Power over Ethernet
Power over Ethernet (PoE) supplies DC power to a device connected to a DWL-8220AP
access port. The PoE state depends on whether you enable or disable PoE when you set
the port type.
Caution:
Use the DWS-1008 switch’s PoE only to power D-Link DWL-8220AP access points.
If you enable PoE on ports connected to other devices, damage can result.
To change the PoE state on a port, use the following command:
set port poe
port-list
enable
|
disable