88
CTC EcoZenith i360
rps
-25 -20 -15 -10 -5 0 5 10 15 20 25 30
Max rps
100 (50...120)
The maximum permissible speed of the compressor at
"winter temperature". Sets the compressor’s maximum
speed (R2) at outdoor temperature T2.
Only applies to modulating air-to-water heat pumps.
Ext. noise reduction rps
50 (20...120)
Set the compressor speed value applicable for remote
control.
Read more in the "Def. Remote Control" section of the
"Installer / Define" chapter.
Max rps warm temp
50 (50...120)
The maximum permissible speed of the compressor
at "summer temperature". Sets the compressor’s
maximum speed (R1) at outdoor temperature T1.
Only applies to modulating air-to-water heat pumps.
Noise reduction, schedule
This menu starts a weekly program with limited
compressor speed to reduce the noise level.
The "Weekly Program" chapter describes how to set
schedules.
Charge pump
50% (In Progress, 25, 100)
Charge pump speed in %.
The speed is calculated using the “Auto adj. charge
pump” function.
The speed can also be programmed manually. If the
speed is selected manually, this value is displayed in
red.
The value is also displayed in red on installation as “Auto
adj. charge pump” has not been run.
If a value of 100 is reached and displayed in red there is
insufficient flow to the heat pump.
If a value of 25 is reached and displayed in red the flow
to the heat pump is higher than optimal.
Auto adj. charge pump
This function starts the calculation of the optimal charge
pump speed. The function is activated by marking the
“Auto adj. charge pump” line and pressing “OK”. While
calculation is in progress, "In Progress" is displayed
below the "Charge Pump" row. Once calculation is
compete the new value is placed in the "Charge Pump"
row, e.g. 72%
The calculation takes about 5 min. DO NOT touch the
screen when the text "In Progress" is displayed.
Different operating modes and seasons may produce
differing results. Any calculation should therefore be
repeated after 4 weeks.
The diagram shows that the compressor speed is controlled
according to the outdoor temperature.
When the outdoor temperature is below T2, the compressor
speed adjusts up to R1.
When the outdoor temperature exceeds T1, the compressor
speed adjusts down to R1.
These temperature and speed limits are set in the menus on
the left.
Outdoor °C
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...