13.3 Information messages
Information messages are displayed when appropriate and are intended to
inform users about various operational situations.
[I002] HC1 Heating off
[I005] HC2 Heating off
Indicates that the product is in Summer mode. No need
for heating in the current heating system, only hot water.
[I008] Tariff HP off
Indicates that Tariff has switched off the heat pump.
[I009] Compressor blocked
The compressor is set to be shut down, e.g. before
drilling or digging has been carried out for the collector
coils. The product comes with the compressor switched
off. This option is selected in the "Installer/Settings/Heat
Pump" menu.
[I010] Tariff El off
Indicates that Tariff has switched off the electric heater.
[I011] Round circulation
Indicates that Round circulation is active. Round
circulation is a device which can be fitted by an electricity
supplier in order to disconnect equipment with a high
rate of electricity consumption for a short period of time.
Not currently in use in the UK. The compressor and
electrical output are blocked when Round circulation is
active.
[I012] High curr., reduced elec.
• The property’s main fuses risk being overloaded
due to, for example, the simultaneous use of
several power-hungry appliances. The product
reduces the electrical heaters’ electrical output
during this period.
• 2h max. 6 kW. Electric heating elements are limited
to 6 kW for 2 hours after being switched on. This
message appears if more than 6 kW are required
during the product's first 2 hours of operation.
This is applicable after a power outage or a new
installation.
[I013] Start delay
The compressor is not allowed to start too quickly after it
has stopped. The delay is usually at least 10 minutes.
[I014] Drying period active, d
Indicates that the floor function is active and displays the
time (days) remaining that the function will be active.
[I017] SmartGrid: Block
[I019] SmartGrid: Low price
[I018] SmartGrid: Overcapacity
Product functionality is governed by "SmartGrid". Also
refer to the "Installer/Define/Remote Control/SmartGrid"
menu.
[I021] Ext. Ctrl Heating 1
[I022] Ext. Ctrl Heating 2
Remote control governs whether the heat in the heating
system is to be switched on or off. If the heating is
switched off, "Heating off, heating circuit 1/2" is also
displayed.
[I028] Holiday period
Displayed when setting the holiday schedule, which
entails lowering the room temperature and that no hot
water is produced.
[I029] Bleeding DHW in progress
During the bleeding process, hot water will not be
supplied at a continuous temperature. Hot water
production can start when the bleeding process is
complete and the message is no longer displayed.
[I030] Driver block under voltage
The heat pump has stopped due to insufficient mains
voltage. The product will attempt to restart.
[I031] Driver block alarm
The heat pump has stopped due to driver failure; for
example, voltage or excessive temperature. The product
will attempt to restart.
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...