105
CTC EcoZenith i360
On menu bar "Block. passive cooling ext. config.", the normal
mode is specified for the external control signal ("Normally
Open (NO)" or "Normally Closed (NC)").
Setting the "Extra DHW" in the "DHW" menu.
Block Passive cooling
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Passive Cooling" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC)).
In the "Installer/Settings/Passive Cooling" menu:
• set the "remote control mode" ("On") in the "Block.
passive cooling config." row.
Access function scheduling from the "Block. ext. config."
row.
For more information, refer to the "Passive Cooling"
section in the "Installer/Settings" chapter.
Menu: "Installer/Define/DHW" On menu bar "Extra DHW",
the normal mode is specified for the external control signal
("Normally Open (NO)" or "Normally Closed (NC)").
Extra DHW
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
Upon activation, production of extra DHW begins. When
activation stops, extra DHW is produced for a run-on
time of 30 min. The "Stop temperature" for extra DHW is
set in the "Installer/Settings /DHW Tank/DHW program"
menu.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/DHW" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "Extra DHW" row.
Setting extra DHW production to start immediately can
also be done in the "DHW" menu. The weekly program
for extra DHW can also be set in this menu.
For more information, refer to the "Extra DHW" section
in the "DHW" chapter.
For more information, refer to the "Upper Tank" section
in the "Installer/Settings" chapter.
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...