100
CTC EcoZenith i360
Menu: "Installer/Settings/Current Sensors".
12.10.10 Settings Current sensor
These menu bars are displayed if "Current Sensor" is
defined in the "Installer/Define Current Sensor" menu.
In the menu, specify the phases (L1, L2 and L3) to
which the current sensors have been connected.
In the lower left corner of the screen, "Invalid
configuration" will be displayed until L1, L2, and L3 are
paired with the three current sensors in the menu.
When activating the "Auto config. current sensors"
function, it is important that you have switched off
all devices in the house that consume high levels of
electricity. Also make sure that the backup thermostat is
switched off.
Menu: "Installer/Settings/Round circulation".
12.10.11 Settings Round circulation
schedule
Round circulation is equipment which an electricity
supplier can fit in order to disconnect, for a short period
of time, equipment which draws high current. The
compressor and electrical output are blocked when
Round circulation is active.
This menu bar is displayed if a weekly program has
been defined for the "Round circulation" function.
The "Round circulation" function can also be controlled
remotely by activating the "Input" defined for the
function.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" of the
"Installer / Define" chapter for defining the remote
control function.
Menu: "Installer/Settings/Current Sensors /Auto config. current
sensor".
Содержание EcoZenith i350 L 1x230V
Страница 3: ...162 505 77 1 2020 09 15 Installation and Maintenance Manual CTC EcoZenith i360 ...
Страница 127: ...127 CTC EcoZenith i360 ...
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 77 1 2020 09 15 ...